Heat transfer fluids

Bolztherm AW-55


Bolztherm AW-55

BOLZTHERM® AW-55 is suitable for use in the liquid phase in closed, non-pressurized heat transfer systems with forced circulation, operating in a temperature range from -28 °C to 315 °C, provided that the maximum film temperature of 340 °C is not exceeded. The optimal operating range is between 80 °C and 280 °C. For applications outside this optimal range, please contact us.

Typical characteristics Unit Standard Value
Area of application [°C] - -28 to 315
Max. flow temperature [°C] - 315
Max. film temperature [°C] - 340
Viscosity at 40 °C [mm²/s] DIN 51562-1 19
Viscosity at 100 °C [mm²/s] DIN 51562-1 2.88
Density at 20 °C [kg/m³] DIN 51757 873
Pourpoint [°C] DIN ISO 3016 -54
Flash point [°C] DIN EN ISO 2719 180
Flash point [°C] DIN EN ISO 2592 193
Acid value [mg KOH/g] DIN ISO 6618 ≤ 0.2
Coke residue [w.-%] DIN EN ISO 10370 < 0.1
Boiling point at 1013 mbar [°C] - 351

More Info (Downloads):

Download Safety data sheet:
Safety data sheet

Download technical data sheet:
Please enter your email address to download the technical data sheet.
Technical Data Sheet